BS EN 621:2009 - Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

BS EN 621:2009

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

Status : Superseded, Withdrawn   Published : January 2010 Replaced By : BS EN 17082:2019

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001


This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters not exceeding a net heat input of 300 kW with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This European Standard applies to Type B11, B41, C11 and C31 appliances intended for use in other than single unit residential dwellings. Provision of the heated air may be by means of ducting or may be directly into the heated space. This standard does not apply to: a) appliances intended for use in a single unit residential dwelling; b) appliances of the condensing type; c) appliances for outdoor installation; d) dual purpose air conditioning appliances (heating and cooling); e) appliances where the air is heated by an intermediate fluid; f) appliances with forced draught burners; g) appliances fitted with a manual or automatic means of adjusting the combustion air supply or the combustion products evacuation (including flue dampers); h) portable or transportable forced convection appliances; i) appliances having multiple heating units with a single draught diverter; j) appliances fitted with more than one flue outlet; k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for appliances which are not type tested would need to be subject to further consideration.




Standard NumberBS EN 621:2009
TitleNon-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products
StatusSuperseded, Withdrawn
Publication Date31 January 2010
Confirm Date23 September 2014
Withdrawn Date05 November 2019
Normative References(Required to achieve compliance to this standard)EN 437:2003, ISO 1182, EN ISO 228-1, EN 61058-1, EN 60584-1, IEC 60584-2:1982, EN 10226-1, EN 10226-2, ISO 7005-3, IEC 61058-1:2000/AMD 1:2001, EN 60730-2-9:2002, EN 125, IEC 60529:1989, EN 60335-2-102, EN 88-1, IEC 60730-1:1999, EN 257, CR 1404, ISO 7005-2, EN 126, IEC 60335-1:2001, ISO 7005-1, IEC 60335-2-102:2004, IEC 60584-2:1982/AMD 1:1989, IEC 61058-1:2000, EN 60584-2:1993, EN 60730-1, EN 60335-1, IEC 60730-2-9:2000, IEC 60584-1:1995, EN 161:2007, ISO 228-1:2000, EN 1859:2000, EN 298:2003, EN 60529:1991
Informative References(Provided for Information)ISO 6976:1995/Corrigendum 1:1997, ISO 6976:1995/Corrigendum 2:1997, 89/106/EEC, ISO 6976:1995/Corrigendum 3:1999, EN ISO 3166-1, EN ISO 6976:2005, ISO 3166-1:2006, ISO 2859-1, ISO 6976:1995
Replaced ByBS EN 17082:2019
ReplacesBS EN 621:1998
International RelationshipsEN 621:2009
Draft Superseded By07/30163658 DC
DescriptorsDesign, Instructions for use, Leak tests, Ignition systems (heat engineering), Commercial, Performance testing, Air heaters, Temperature-rise limit, Circuits, Installation, Gas space heating, Control devices, Fire safety, Heaters, Gas valves, Flues, Heating equipment, Flames, Combustion products, Classification systems, Fire tests, Electrical equipment, Performance, Convection heaters, Ignition, Commissioning, Testing conditions, Gases, Cut-out devices, Conversion, Gas-powered devices, Safety measures, Safety devices, Marking
ICS97.100.20
Title in FrenchGénérateurs d'air chaud à convection forcée utilisant les combustibles gazeux pour le chauffage de locaux autres que l'habitat individuel, de débit calorifique sur Hi inférieur ou égal à 300 kW, sans ventilateur pour aider l'alimentation en air comburant et/ou l'évacuation des produits de combustion
Title in GermanGasbefeuerte Warmlufterzeuger mit erzwungener Konvektion zum Beheizen von Räumen für den nichthäuslichen Gebrauch mit einer Nennwärmebelastung nicht über 300 kW, ohne Gebläse zur Beförderung der Verbrennungsluft und/oder der Abgase
CommitteeGSE/20
ISBN978 0 580 58602 6
PublisherBSI
FormatA4
DeliveryYes
Pages116
File Size1.448 MB
Price£292.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world