BS EN 61000-4-6:2009 - Electromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields – BSI British Standards

BS EN 61000-4-6:2009

Electromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields

Status : Superseded, Withdrawn   Published : May 2009 Replaced By : BS EN 61000-4-6:2014

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


BS EN 61000-4-6:2009 Electromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields

BS EN 61000-4-6 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded.

BS EN 61000-4-6 defines test methods for measuring the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods defined are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.

BS EN 61000-4-6 establishes a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by radio-frequency fields. The test method documented in BS EN 61000-4-6 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.

Contents of BS EN 61000-4-6:

  • Introduction
  • Scope and object
  • Normative references
  • Terms and definitions
  • General
  • Test levels
  • Test equipment
  • Test generator
  • Coupling and decoupling devices
  • Coupling/decoupling networks (CDNs)
  • Clamp injection devices
  • Direct injection devices
  • Decoupling networks
  • Verification of the common mode impedance at the EUT port of coupling and decoupling
  • devices
  • Insertion loss of the 150 Ω to 50 Ω adapters
  • Setting of the test generator
  • Setting of the output level at the EUT port of the coupling device
  • Test set-up for table-top and floor-standing equipment
  • Rules for selecting injection methods and test points
  • Injection method
  • Ports to be tested
  • Procedure for CDN injection application
  • Procedure for clamp injection when the common-mode impedance requirements can be met
  • Procedure for clamp injection when the common-mode impedance requirements cannot be met
  • Procedure for direct injection
  • EUT comprising a single unit
  • EUT comprising several units
  • Test procedure
  • Evaluation of the test results
  • Test report



Standard NumberBS EN 61000-4-6:2009
TitleElectromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields
StatusSuperseded, Withdrawn
Publication Date31 May 2009
Withdrawn Date27 November 2016
Normative References(Required to achieve compliance to this standard)IEC 60050-161
Informative References(Provided for Information)77/349/INF, CISPR 16-1-2, IEC TC77, EN 55020:2007, IEC 61000-4-3, EN 61000-4-3:2006, EN 55016-1-2:2004, CISPR 20, IEC 60050-131:2002
Replaced ByBS EN 61000-4-6:2014
ReplacesBS EN 61000-4-6:2007
International RelationshipsIEC 61000-4-6:2008,EN 61000-4-6:2009
DescriptorsElectrical equipment, Electromagnetic compatibility, Electromagnetic radiation, Test equipment, Circuits, Selection, Electrical testing, Electronic equipment and components, Electromagnetic fields, Noise (spurious signals), Calibration, Radiofrequencies, Electric power system disturbances, Radio disturbances
ICS17.220.20
33.100.20
Title in FrenchCompatibilité électromagnétique (CEM). Techniques d'essai et de mesure. Immunité aux perturbations conduites, induites par les champs radioélectriques
Title in GermanElektromagnetische Verträglichkeit (EMV). Prüf- und Messverfahren. Störfestigkeit gegen leitungsgeführte Störgrößen, induziert durch hochfrequente Felder
CommitteeGEL/210/11
ISBN978 0 580 57232 6
PublisherBSI
FormatA4
DeliveryNo
Pages60
File Size1.703 MB
Price£254.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world


Customers who bought this product also bought

  • BS EN 61000-4-2:2009
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Electrostatic discharge immunity test
  • BS EN 61000-4-3:2006+A2:2010
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Radiated, radio-frequency, electromagnetic field immunity test
  • BS EN 61000-4-8:2010
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Power frequency magnetic field immunity test
  • BS EN 61000-4-4:2012
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Electrical fast transient/burst immunity test