BS 7967-4:2007 - Carbon monoxide in dwellings and the combustion performance of gas-fired appliances. Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances – BSI British St

BS 7967-4:2007

Carbon monoxide in dwellings and the combustion performance of gas-fired appliances. Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances

Status : Superseded, Withdrawn   Published : June 2007 Replaced By : BS 7967:2015

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001


This part of BS 7967 gives guidance on the use of an electronic portable combustion gas analyser as a diagnostic instrument to assist a gas operative:

  • In determining the level of servicing required for a gas-fired appliance
  • In confirming satisfactory combustion following servicing in accordance with manufacturer’s instructions
  • In confirming satisfactory combustion following maintenance.

This standard is intended to ensure the safe and efficient operation, in dwellings, of:

  • Flueless gas-fired appliances (type A gas-fired appliances), e.g. cooking appliances, space heaters
  • Open flued appliances (type B gas-fired appliances)
  • Room sealed appliances (type C gas-fired appliances).

Contents include:

Scope
Normative references
Terms and definitions
Electronic portable combustion gas analyser
Procedure for servicing and maintenance using an electronic portable combustion gas analyser
Completion report
Background to the use of an electronic portable combustion gas analyser in regular servicing
Bibliography

Figures include:

  • Procedure for use of an electronic portable combustion gas analyser to determine whether or not the combustion performance is satisfactory, and the subsequent actions to be performed.
  • Procedure for the use of an electronic portable combustion gas analyser as an aid to checking combustion performance subsequent to servicing carried out in accordance with manufacturer’s instructions.
  • Procedure for the use of an electronic portable combustion gas analyser to confirm satisfactory combustion following maintenance.



Standard NumberBS 7967-4:2007
TitleCarbon monoxide in dwellings and the combustion performance of gas-fired appliances. Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances
StatusSuperseded, Withdrawn
Publication Date29 June 2007
Confirm Date01 October 2012
Withdrawn Date28 February 2015
Normative References(Required to achieve compliance to this standard)BS 7967-3:2005, BS 7967-2:2005, BS EN 50379-3
Informative References(Provided for Information)Gas Safety (Installation and Use) Regulations, HSE CHAN 29, BS 7927:1998/AMD 1:1998, (Northern Ireland) 2004, Gas (Application) Order (Isle of Man) 1996, Occurrences Regulations 1995, HSE CHAN 28, PD CEN/TR 1749, Gas (Management) Regulations 1996, HSC L56, Gas (Installation and Use) Regulations 1998, CORGI The Gas Industry Unsafe Situations Procedure., Dealing with unsafe situations in customers premises, 1997, Reporting of Injuries, Diseases and Dangerous, Gas Safety (Management) Regulations (Northern Ireland)
Replaced ByBS 7967:2015
Draft Superseded By06/30112198 DC
DescriptorsSafety measures, Gas-fired heaters, Gas analysis, Gas detectors, Domestic, Performance, Boilers, Portable, Gas-powered devices, Carbon dioxide, Combustion, Combustion products, Carbon monoxide, Maintenance, Gas analyzers, Buildings, Cookers
ICS13.040.40
97.100.20
CommitteeGSE/30/-/21
ISBN978 0 580 50852 3
PublisherBSI
FormatA4
DeliveryNo
Pages22
File Size276 KB
Price£130.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • BS 7967-2:2005
    Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance
  • BS 7967-3:2005
    Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers
  • BS 7967-1:2005
    Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation
  • BS 5871-4:2007
    Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW (2nd and 3rd family gases)