BS EN 12845:2004+A2:2009

Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance

Status : Current   Published : November 2004

Price
£ 228.00
Member Price
£ 114.00


BS EN 12845:2004+Amendment 2:2009 Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance

BS EN 12845 specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plants. It gives particular requirements for sprinkler systems, which are important when measuring protection.

The requirements and recommendations of this standard also apply to any addition, extension, repair or other modification to a sprinkler system. They do not apply to water spray or deluge systems.

BS EN 12845 covers the classification of hazards, provision of water supplies, components to be used, installation and testing of the system, maintenance, and the extension of existing systems. It identifies construction details of buildings, which are the minimum necessary for satisfactory performance of sprinkler systems complying with this standard.

BS EN 12845 does not cover water supplies to systems other than sprinklers. Its requirements can be used as guidance for other fixed fire fighting extinguishing systems, however, provided that any specific requirements for other fire fighting extinguishing supplies are taken into account.
This standard also covers sprinkler kits where a kit includes all the components necessary to complete the installed sprinkler system.

The requirements are not valid for automatic sprinkler systems on ships, in aircraft, on vehicles and mobile fire appliances or for below ground systems in the mining industry.
The 2009 amendments to BS EN 12845 include a CEN update and corrections to the national foreword.

Contents of BS EN 12845:

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Contract planning and documentation
5 Extent of sprinkler protection
6 Classification of occupancies and fire hazards
7 Hydraulic design criteria
8 Water supplies
9 Type of water supply
10 Pumps
11 Installation type and size
12 Spacing and location of sprinklers
13 Pipe sizing and layout
14 Sprinkler design characteristics and uses
15 Valves
16 Alarms and alarm devices
17 Pipework
18 Signs, notices, and information
19 Commissioning
20 Maintenance
Annex A (normative) Classification of typical hazards
Annex B (normative) Methodology for categorizing stored goods
Annex C (normative) Alphabetical listing of stored products and categories
Annex D (normative) Zoning of sprinkler installations
Annex E (normative) Special requirements for high rise systems
Annex F (normative) Special requirements for life safety systems
Annex G (normative) Protection of #deleted text$ special hazards
Annex H (normative) Sprinkler systems monitoring
Annex I (normative) Transmission of alarms
Annex J (informative) Precautions and procedures when a system is not fully operational
Annex K (informative) Twenty-five year inspection
Annex L (informative) Special technology
Annex M (informative) Independent certification body
Bibliography



Standard NumberBS EN 12845:2004+A2:2009
TitleFixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance
StatusCurrent
Publication Date16 November 2004
Cross ReferencesEN 54-1, EN 54-2, EN 54-3, EN 54-4, EN 54-5, EN 54-10, EN 54-11, EN 287-1, EN 1057, EN 1254, EN 12259-1, EN 12259-2, EN 12259-3, EN 12259-4, EN 12259-5, prEN 12259-12, EN 12723, EN 50342-1, EN 50342-2, EN 60529, EN 60529, IEC 60529:1989, EN 60623, IEC 60623:2001, EN 60947-1, IEC 60947-1:2007, EN 60947-4, IEC 60947-4-1:2000, EN ISO 3677, ISO 3677:1992, ISO 65, ISO 3046, EN ISO 9001, ISO 9001:2000, EN 671
ReplacesBS EN 12845:2003
International RelationshipsEN 12845:2004 Identical
Amended ByAmendment July 2009. Amends and replaces BS EN 12845:2004. Corrigendum August 2009.
DescriptorsFire sprinklers, Fire extinguishers, Fixed, Firefighting equipment, Automatic control systems, Fire safety in buildings, Fire extinguishers (built-in), Installation, Design, Maintenance, Classification systems, Hazards, Water supply (buildings), Performance testing
ICS13.220.20 (Fire protection)
Title in FrenchInstallations fixes de lutte contre l'incendie. Systèmes d'extinction automatiques du type sprinkleur. Conception, installation et maintenance
Title in GermanOrtsfeste Brandbekämpfungsanlagen. Automatische Sprinkleranlagen. Planung, Installation und Instandhaltung
CommitteeFSH/18/2
ISBN978 0 580 68733 4
PublisherBSI
FormatA4
DeliveryYES
Pages184
File Size1.637 MB
NotesThis standard is the subject of transitional arrangements agreed under a European Commission mandate and is intended to lead to CE marking in support of the Construction Products Directive. In order to allow for any changes in national regulations, the Commission in consultation with Member States have agreed a transition period for the co-existence of EN 12845 and corresponding national standards. Therefore at the end of this period BS 5306-2:1990 will be withdrawn.
Price£ 228.00


 Your basket
Your basket is empty

Customers who bought this product also bought

  • BS 5306-3:2009
    Fire extinguishing installations and equipment on premises. Commissioning and maintenance of portable fire extinguishers. Code of practice

See our Standards Development website

Make your comments count

Join us online - find out how...

Find out how Medecedes F1 team use standards to win