BS EN 61000-3-3:2008 - Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional conn

Find Similar Items

This product falls into the following categories.

You may find similar items within these categories by selecting from the choices below:

BS EN 61000-3-3:2008

Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

Status : Revised, Withdrawn   Published : December 2008 Replaced By : BS EN 61000-3-3:2013

WITHDRAWN TITLE
*To ask about withdrawn titles contact the BSI Knowledge Centre knowledgecentre@bsigroup.com,
+44 20 8996 7004


BS EN 61000-3-3:2008 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

BS EN 61000-3-3 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system.

It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment.

BS EN 61000-3-3 is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to
conditional connection.

BS EN 61000-3-3 contains:

  • Normative references
  • Definitions
  • Assessment of voltage changes, voltage fluctuations and flicker 8
  • Limits
  • Test conditions.

Equipment which does not comply with the limits of this part of IEC 61000 when tested with the reference impedance Zref of 6.4, and which therefore cannot be declared compliant with this part, may be retested or evaluated to show conformity with IEC 61000-3-11. Part 3-11 is applicable to equipment with rated input current ≤75 A per phase and subject to conditional connection.

The tests according to this part are type tests. Particular test conditions and the test cicuit are given.

BS EN 61000-3-3:2008  supercedes BS EN 61000-3-3:1995, which will be withdrawn on 1 September 2011.




Standard NumberBS EN 61000-3-3:2008
TitleElectromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
StatusRevised, Withdrawn
Publication Date31 December 2008
Withdrawn Date18 June 2016
Cross ReferencesIEC 60050-161:1990, IEC/TR 60725, IEC 60974-1, IEC 61000-3-2:2005, IEC 61000-3-11, IEC 61000-4-15, EN 60974-1:2005, EN 61000-3-2:2006, EN 61000-3-11:2000, EN 61000-4-15:1998, 2004/108/EC, 1999/5/EC
Replaced ByBS EN 61000-3-3:2013
ReplacesBS EN 61000-3-3:1995+A2:2005, IEC 61000-3-3:1994
International RelationshipsEN 61000-3-3:2008,IEC 61000-3-3:2008
DescriptorsElectromagnetic compatibility, Electromagnetic radiation, Electromagnetic fields, Electric power system disturbances, Household equipment, Electrically-operated devices, Electronically-operated devices, Voltage fluctuations, Voltage measurement, Electrical measurement, Mathematical calculations, Electrical wave measurement, Magnetic fields, Noise (spurious signals), Rated current, Type testing, Domestic electrical installations, Cookers, Lighting equipment, Washing machines, Water heaters, Tumble driers
ICS33.100.10
Title in FrenchCompatibilité électromagnétique (CEM). Limites. Limitation des variations de tension, des fluctuations de tension et du papillotement dans les réseaux publics d'alimentation basse tension, pour les matériels ayant un courant assigné ≤ 16 A par phase et non soumis à un raccordement conditionnel
Title in GermanElektromagnetische Verträglichkeit (EMV). Grenzwerte. Begrenzung von Spannungsänderungen, Spannungsschwankungen und Flicker in öffentlichen Niederspannungs-Versorgungsnetzen für Geräte mit einem Bemessungsstrom ≤ 16 A je Leiter, die keiner Sonderanschlussbedingung unterliegen
CommitteeGEL/210/11
ISBN978 0 580 59102 0
PublisherBSI
FormatA4
DeliveryNo
Pages28
File Size1.72 MB
Price£158.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the BSI Knowledge Centre knowledgecentre@bsigroup.com,
+44 20 8996 7004
 Your basket
Your basket is empty

Take the smart route to manage medical device compliance


Worldwide Standards
We can source any standard from anywhere in the world


BSI Essentials

Get ISO 9001 and ISO 9000 with 15% discount.


ISO 13485

The world's most popular standard for medical devices quality management


Customers who bought this product also bought

  • BS EN 61000-3-2:2006+A2:2009
    Electromagnetic compatibility (EMC) Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • BS EN 61000-4-11:2004
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Voltage dips, short interruptions and voltage variations immunity tests
  • BS EN 61000-4-2:2009
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Electrostatic discharge immunity test
  • BS EN 61000-4-5:2006
    Electromagnetic compatibility (EMC) Testing and measurement techniques