BS 9999:2008

Code of practice for fire safety in the design, management and use of buildings

Status : Current   Published : October 2008

Price
£ 290.00
Member Price
£ 145.00
BS 9999 front cover


After 10 years in development, BSI British Standards has published BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings.

BS 9999 gives recommendations and guidance on the design, management and use of buildings to achieve acceptable levels of fire safety for all people in and around buildings.

BS 9999 is applicable to the design of new buildings, and to alterations, extensions and changes of use of an existing building, with the exception of individual homes and with limited applicability in the case of certain specialist buildings. It also provides guidance on the ongoing management of fire safety in a building throughout the entire life cycle of the building, including guidance for designers to ensure that the overall design of a building assists and enhances the management of fire safety. It can be used as a tool for assessing existing buildings, although fundamental change in line with the guidelines might well be limited or not practicable.

BS 9999 contributes to the protection of people in buildings by:

  • Working to prevent fires occurring in the first place
  • Being aware of the types of people in the building and any special risks or needs (such as disabled people, see BS 8300 Design of buildings and their approaches to meet the needs of disabled people. Code of practice)
  • Ensuring that all of the fire safety measures in the building are kept in working order, and in particular that the means of escape are always available
  • Training staff and organizing the evacuation plan, to ensure that occupants leave quickly if a fire occurs
  • Taking command in the event of a fire until the fire and rescue service arrives.

The standard builds on government guidance to legislative requirements, providing an advanced approach to fire safety in the design, management and use of buildings.  It promotes a more flexible approach to fire safety design through use of structured risk-based design where designers can take account of varying human factors.  The guidance on means of escape for disabled people (in respect of both design and management) is greatly expanded within BS 9999 from that in DD 9999 to reflect the requirements of the Disability Discrimination Act and the principles of inclusive design.

Who should use BS 9999?

  • Architects
  • Designers
  • Surveyors
  • Facilities/building managers
  • Fire and rescue service 
  • Building control officers 
  • Fire safety engineers 
  • Fire risk consultants
  • NRAC and other qualified access consultants.

BS 9999 will supersede DD 9999, and the entire BS 5588 series (with the exception of BS 5588-1), which will be withdrawn on 6 April 2009.

 

 

The BS 9999 Handbook. Effective Fire Safety in the Design, Management and Use of Buildings 
Michael Green and Jonathan Joinson

Download chapter 1 of the guide to BS9999
Read more and buy the guide to BS 9999



Standard NumberBS 9999:2008
TitleCode of practice for fire safety in the design, management and use of buildings
StatusCurrent
Publication Date31 October 2008
Cross ReferencesBS 476, BS 799-5, BS 1635, BS 3251, BS 4533, BS 4790, BS 5234, BS 5266-1, BS EN 1838, BS 5306-0, BS 5306-1, BS 5306-2, BS 5306-3, BS 5306-4, BS 5306-5, BS 5306-6, BS 5306-8, BS 5395-1, BS 5395-2, BS 5410-1, BS 5410-2, BS 5438:1989+A2:1994, BS 5499, BS 5651, BS 5655-6, BS 5656-1, BS 5656-2, BS 5839-1:2002+A2:2008, BS 5839-3, BS 5839-9:2003, BS 5852:2006, BS 5867-2:2008, BS 5906, BS 6180, BS 6262-4, BS 6263-2, BS 6644, BS 6798, BS 7036, BS 7157:1989, BS 7176, BS 7273-4, BS 7346-3, BS 7346-4, BS 7346-6, BS 7346-7:2006, BS 7671, BS 7807, BS 8214, BS 8300, BS 8313, BS 8414-1, BS 8414-2, BS 8486-1, BS 8486-2, BS 9251, BS 9990, BS EN 54-7, BS EN 54-11:2001+A1:2006, BS EN 81, BS EN 115, BS EN 378, BS EN 671, BS EN 1125, BS EN 1154, BS EN 1155, BS EN 1363, BS EN 1364, BS EN 1365, BS EN 1366, BS EN 1634-1, BS EN 1634-3, BS EN 12101, BS EN 12150-1, BS EN 12416-2, BS EN 12845, BS EN 13501, BS EN 13823, BS EN 14179-1, BS EN 60702-1, BS EN 60702-2, BS EN ISO 306, BS EN ISO 1182, BS EN ISO 1716, BS EN ISO 12543-2, BS EN ISO 14122-4, BS ISO 10294-5, BS ISO 14520, ISO 834-1, BS 2782, BS 4422, BS 4514, BS 5255, BS 5516-2, BS 5655-11, BS 5655-12, BS 6133, BS 6187, BS 6266, BS 6336, BS 7974, BS 25999-1, PD 6520, PD 7974-1, PD 7974-3, PD 7974-7, BS EN 179, BS EN 1021-1, BS EN 1021-2, BS EN 1158, BS EN 1366-7, BS EN 1991-1-2, BS EN 1993-1-2, BS EN ISO 13943, BS EN ISO 9000, DD ENV 1187:2002, CEN/CENELEC Guide 6
ReplacesBS 5588-0:1996, BS 5588-12:2004, BS 5588-5:2004, BS 5588-8:1999, BS 5588-10:1991, BS 5588-11:1997, BS 5588-6:1991, BS 5588-7:1997, BS 5588-9:1999, DD 9999:2005
Supersedes Draft08/30158435 DC
DescriptorsFire safety in buildings, Fire safety, Risk assessment, Management, Buildings by fire risk categories, Means of escape from fire in buildings, Crowd safety, Fire-escape routes, Emergency exits, Emergency lighting, Circulation and space systems (buildings, Structural fire protection, Fire spread prevention, Fire-resistant materials, Fire doors, Hazard prevention in buildings, Firefighting, Firefighting equipment, Fire sprinklers, Fire alarms, Lifts, Atria (buildings), Assembly facilities, Seating, Buildings open to the public, Shops (buildings), Shopping centres, Disabled people
ICS13.220.01 (Protection against fire in general)
91.040.01 (Buildings in general)
CommitteeFSH/14
ISBN978 0 580 57920 2
PublisherBSI
FormatA4
DeliveryYES
Pages458
File Size2.229 MB
Price£ 290.00