Find Similar Items

This product falls into the following categories.

You may find similar items within these categories by selecting from the choices below:

Result Types

Industry Sector

Committee

ICS Category

PD 7974-4:2003

Application of fire safety engineering principles to the design of buildings. Detection of fire and activation of fire protection systems. (Sub-system 4)

Status : Current   Published : March 2003

Price
£ 142.00
Member Price
£ 71.00


This Published Document provides guidance on the development, design and application of fire detection systems, and the activation of fire alarm and fire control systems to fulfil a role in the fire safety engineered design for a building. Scientific and engineering principles are used as part of a structured approach. The key elements covered are:

  • detection: information is provided on the various types of fire detection system and their application for a given set of circumstances, as derived from a qualitative design review, risk assessment and the results of formulae provided by other Sub-systems;
  • activation and control: once the fire detection system has detected a fire, it activates a series of measures designed to fulfil the requirements of the fire safety engineered design. These measures may include operation of fire warning systems, the remote signalling to emergency services, and the operation of fire alarm, fire suppression and fire control systems. Guidance is given on the methodology and formulae required in ensuring that the appropriate systems are activated in an appropriate manner and within given criteria.

In the context of this document, fire control includes:

  • fire suppression systems: active systems designed to suppress a fire, temporarily (i.e. control) or permanently (i.e. extinguish). Examples include automatic water sprinkler systems;
  • fire barrier systems: active systems designed to contain a fire within a given area or separate a fire from another area. Such systems may be regarded as offering similar benefits to passive fire compartments or separations for the duration of their operation. Examples include fire damper systems and door release mechanisms;
  • smoke/heat control systems: active systems designed to positively control the movement and build up of fire effluents such as smoke, heat and toxic gases. Examples include smoke venting systems and air pressurization systems.


Standard NumberPD 7974-4:2003
TitleApplication of fire safety engineering principles to the design of buildings. Detection of fire and activation of fire protection systems. (Sub-system 4)
StatusCurrent
Publication Date14 March 2003
Cross ReferencesBS EN 50131-1, DD 240-1:1997, prEN 54-12, BS 5306-2, BS 5588-4, BS 5839-1, BS 5839-8, BS EN 54-2, BS EN 54-3, BS EN 54-4, BS EN 54-5, BS EN 54-7, BS EN 54-10, BS EN 54-11, BS ISO 14520
DescriptorsFire safety in buildings, Fire safety, Hazard prevention in buildings, Buildings, Design, Safety engineering, Structural fire protection, Fire spread prevention, Means of escape from fire in buildings, Fire alarms, Alarm systems, Fire detectors, Smoke detectors, Automatic control systems
ICS13.220.20 (Fire protection)
91.120.99 (Other standards related to protection of and in buildings)
CommitteeFSH/24/4
ISBN0 580 41249 0
PublisherBSI
FormatA4
DeliveryYES
Pages44
Price£ 142.00


 Your basket
Your basket is empty

Customers who bought this product also bought

  • PD 7974-6:2004
    The application of fire safety engineering priciples to fire safety design of buildings. Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6)
  • PD 7974-7:2003
    Application of fire safety engineering principles to the design of buildings. Probabilistic risk assessment
  • PD 7974-1:2003
    Application of fire safety engineering principles to the design of buildings. Initiation and development of fire within the enclosure of origin (Sub-system 1)
  • PD 7974-2:2002
    Application of fire safety engineering principles to the design of buildings. Spread of smoke and toxic gases within and beyond the enclosure of origin (Sub-system 2)

Make your comments count

Find out how Medecedes F1 team use standards to win

Join us online - find out how...

See our Standards Development website