BS 9999:2017 Code of practice for fire safety in the design, management and use of buildings

Find Similar Items

This product falls into the following categories.

You may find similar items within these categories by selecting from the choices below:

BS 9999:2017

Fire safety in the design, management and use of buildings. Code of practice

Status : Current   Published : January 2017

Not Available
This title is not for sale through this shop.
To preorder this title, please contact customer service: Tel: +44 345 086 9001
Email: cservices@bsigroup.com


BS 9999:2017 Code of practice for fire safety in the design, management and use of buildings

What is BS 9999?

BS 9999 gives recommendations and guidance on the design, management and use of buildings to achieve reasonable standards of fire safety for all people in and around them. It also provides guidance on the on-going management of fire safety within a building throughout its entire life cycle, including guidance for designers to ensure that the overall design of a building assists and enhances the management of fire safety.

This British Standard is applicable to the design of new buildings, and to alterations, extensions and changes of use of an existing building. It can be used as a tool for assessing existing buildings, although fundamental change in line with the guidelines might well be limited or not practicable. The recommendations and guidance given in this British Standard are intended to safeguard the lives of building occupants and fire-fighters. Whilst some of the recommendations and guidance might also assist in the achievement of other fire safety objectives – such as protection of property, the environment, communities and business/service viability – additional measures might be necessary which are outside the scope of this British Standard.

It is not applicable to individual dwelling-houses, and might have only limited applicability to certain specialist buildings and areas of buildings (e.g. hospitals and areas of lawful detention).  

What's new?

BS 9999 is being fully revised to align with current practices, new technology and other parts of the fire safety standards series, namely BS 9990 and BS 9991. The new edition of BS 9999 will introduce the following changes:

  • Inclusion of flowchart showing the sequential steps in the design process, to assist users in the application of the standard
  • Revised clause on fire safety management with references to PAS 7
  • Inclusion of watermist fire suppression systems
  • Expansion of guidance on voice alarms
  • Expansion of fire growth rates table to provide more information
  • Removal of content now covered by BS 9991
  • General update to take into account new and revised standards published since 2008

The standard also features revised recommendations for:

  • Smoke and heat control
  • Fire curtain barrier assemblies
  • Mechanical ventilation and air-condition systems
  • Shopping complexes
  • Building exits
  • Ducting

Who should buy it?

  • Architects
  • Fire safety engineers
  • Fire risk assessors
  • Building control
  • Installers of fire and smoke alarms, sprinklers and smoke and heat control systems
  • Inspectorate for certification and installation schemes
  • Those involved in emergency lighting



Standard NumberBS 9999:2017
TitleFire safety in the design, management and use of buildings. Code of practice
StatusCurrent
Publication Date31 January 2017
Cross ReferencesBS 476, BS 799-5, BS 1635, BS 3251, BS 4533, BS 4790, BS 5234, BS 5266-1, BS 5306-0, BS 5306-1, BS 5306-2, BS 5306-3, BS 5306-4, BS 5306-8, BS 5395-1, BS 5395-2, BS 5410-1, BS 5410-2, BS 5499-4, BS 5651, BS 5655-6, BS 5656-1, BS 5656-2, BS 5656-3, BS 5839-1:2013, BS 5839-8:2013, BS 5839-9:2011, BS 5852:2006, BS 5867-2:2008, BS 5906, BS 6180, BS 6262-4, BS 6263-2, BS 6266, BS 6644, BS 6798, BS 7036-0, BS 7157:1989, BS 7176, BS 7273-4:2015, BS 7346-4, BS 7346-7, BS 7346-8, BS 7671, BS 8214, BS 8300, BS 8313, BS 8414-1, BS 8414-2, BS 8486-1, BS 8486-2, BS 8489-1, BS 8519, BS 8524, BS 9251, BS 9990, BS 9991, BS EN 54-11:2001+A1:2006, BS EN 54-23, BS EN 81-20, BS EN 81-58, BS EN 81-70, BS EN 81-71, BS EN 81-72, BS EN 81-73:2016, BS EN 115-1, BS EN 378, BS EN 671, BS EN 1125, BS EN 1154, BS EN 1363, BS EN 1364, BS EN 1365, BS EN 1366, BS EN 1634, BS EN 1838, BS EN 12101, BS EN 12416-2, BS EN 12845, BS EN 13501, BS EN 13565-2, BS EN 13823, BS EN 15650:2010, BS EN 16005, BS EN ISO 1182, BS EN ISO 1716, BS EN ISO 12543-2, BS EN ISO 14122-4, BS ISO 3864-1, BS ISO 14520, DD CEN/TS 14816, BS 2782, BS 4422:2005
ReplacesBS 9999:2008
Draft Superseded By16/30314117 DC
DescriptorsFire safety in buildings, Fire safety, Risk assessment, Management, Buildings by fire risk categories, Means of escape from fire in buildings, Crowd safety, Fire-escape routes, Emergency exits, Emergency lighting, Circulation and space systems (buildings, Structural fire protection, Fire spread prevention, Fire-resistant materials, Fire doors, Hazard prevention in buildings, Firefighting, Firefighting equipment, Fire sprinklers, Fire alarms, Lifts, Atria (buildings), Assembly facilities, Seating, Buildings open to the public, Shops (buildings), Shopping centres, Disabled people
ICS13.220.01
91.040.01
CommitteeFSH/14
ISBN978 0 580 88256 2
PublisherBSI
FormatA4
DeliveryYes
Pages418
File Size5.688 MB
Price£380.00


Not Available
This title is not for sale through this shop.
To preorder this title, please contact customer service: Tel: +44 345 086 9001
Email: cservices@bsigroup.com
 Your basket
Your basket is empty

Take the smart route to manage medical device compliance


Collaborate, Innovate, Accelerate.


BIM Level 2 is here.
We have developed a new website as an official point of reference for using BIM and associated data to increase productivity and reduce waste.


BSOL

The faster, easier way to work with standards